10/2 NM W/GX 100' BUILDING WIRE
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
- NM-B - PVC Jacket - Solid
- Color Coded - Copper W/ Ground
- Shrink Wrap - 2 Conductors
- Color/ Amps : Orange/30
- Wire Size/NumxLgth : 10/2 x 100'
- Non-metallic sheathed cable
- Color coded jacket SIM jacket
- Construction designed for easier pulling
- Four conductor available with two neutrals
- Pulls faster
- Strips easier
- Reduced burn-thru
- Tear resistant
View Details
Call for Price
10/2 UF W/GX 50' BUILDING WIRE
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
- Direct Bury Romex
- Copper - Bare Ground
- 2 Conductors
- Size- Amps : 10/2 - 30
- Lgth Ft : 50
View Details
Call for Price
14/2 UF W/GX 50' BUILDING WIRE
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
- Direct Bury Romexd
- Copper - Bare Ground
- 2 Conductors
- Size- Amps : 14/2 - 15
- Lgth Ft : 50
View Details
Call for Price
12/2UF W/GX 25' BUILDING WIRE
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
- Direct Bury Romex
- Copper - Bare Ground
- 2 Conductors
- Size- Amps : 12/2 - 20
- Lgth Ft : 25
View Details
Call for Price
10/2 UF W/GX 100' BUILDING WIRE
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
- Direct Bury Romex
- Copper - Bare Ground
- 2 Conductors
- Size- Amps : 10/2 - 30
- Lgth Ft : 100
- Underground feeder and branch circuit cable
- Sunlight, moisture, and fungus resistant overall PVC jacket
View Details
Call for Price
14/2 UF W/GX 100' BUILDING WIRE
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
- Direct Bury Romex
- Copper - Bare Ground
- 2 Conductors
- Size- Amps : 14/2 - 15
- Lgth Ft : 100
View Details
Call for Price
12/3 NM W/GX 100' BUILDING WIRE
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
- NM-B - PVC Jacket - Solid
- Color Coded - Copper W/ Ground
- Shrink Wrap - 3 Conductors
- Color/ Amps : Yellow/20
- Wire Size/NumxLgth : 12/3 x 100'
- Non-metallic sheathed cable
- Color coded jacket SIM jacket
- Construction designed for easier pulling
- Four conductor available with two neutrals
- Pulls faster
- Strips easier
- Reduced burn-thru
- Tear resistant
View Details
Call for Price
10/2 UF W/GX 250' BUILDING WIRE
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
- Direct Bury Romex
- Copper - Bare Ground
- 2 Conductors
- Size- Amps : 10/2 - 30
- Lgth Ft : 250
View Details
Call for Price
10/2 WELL WIRE FLAT PER FOOT
10/2 WELL WIRE FLAT PER FOOT
View Details
Call for Price
14/3 NM W/GX 50' BUILDING WIRE
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
- NM-B - PVC Jacket - Solid
- Color Coded - Copper W/ Ground
- Shrink Wrap - 3 Conductors
- Color/ Amps : White/15
- Wire Size/NumxLgth : 14/3 x 50'
View Details
Call for Price
ENTRANCE WIRE 2/2/2 PER FOOT
ENTRANCE WIRE 2/2/2 PER FOOT
View Details
Call for Price
1/2" UF CABLE CONNECTOR
1/2" UF CABLE CONNECTOR
View Details
Call for Price
10/2 UF WG BUILDING WIRE PER FT
10/2 UF WG BUILDING WIRE PER FT
View Details
Call for Price
12 GA SGL STRAND WIRE BLACK 500'
Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. 500 foot spool. UL Listed.
- Stranded Single Wire
- Type THHN - Copper
- Color : Black
- AWG : 12
- Thermoplastic insulation/nylon sheath heat, moisture, gasoline, and oil resistant
- Sizes 8 AWG and larger rated THWN-2 all stranded sizes rated MTW and THWN - Sizes 14 through 6 AWG rated AWM (105 deg C) sizes 14 through 1 AWG rated VW-1
- Size 1/0 AWG and larger listed for CT use black size 2 AWG and larger listed sunlight-resistant
View Details
Call for Price
12 GA SGL STRAND WIRE WHITE 500'
Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. 500 foot spool. UL Listed.
- Stranded Single Wire
- Type THHN - Copper
- Color : White
- AWG : 12
- Thermoplastic insulation/nylon sheath heat, moisture, gasoline, and oil resistant
- Sizes 8 AWG and larger rated THWN-2 all stranded sizes rated MTW and THWN - Sizes 14 through 6 AWG rated AWM (105 deg C) sizes 14 through 1 AWG rated VW-1
- Size 1/0 AWG and larger listed for CT use black size 2 AWG and larger listed sunlight-resistant
View Details
Call for Price